Issue A Rev 2 108469 Telect, Inc.
3-1
DATA SIGNALS
The DCS circuit cables terminate at the lower pair of termination points on
the rear of the DNI-3 panel, labeled NE-1. The OUT cable connects to the
upper NE-1 termination point and the IN cable connects to the lower NE-1
termination point.
The NE circuit cables terminate at the upper pair of termination points on
the rear of the DNI-3 panel, labeled NE-2. The OUT cable connects to the
upper NE-2 termination point and the IN cable connects to the lower NE-2
termination point.
Internally, the DCS circuits and the NE circuits are cross-connected.
R2
R1
R1
R1
R1
R2
M
O
I
M
O
I
O
I
O
I
NE-2
NE-1
RearFront
NE-1
NE-2
R1 = 75, ¼W
R2 = 768, ¼W
3 Electrical Operation